On-site Full Time
--
Mubasher Capital

Job Details

Job Purpose:


The Smart Facilities Monitoring SME is the technical authority for monitoring ZATCA's data centre and smart-facility infrastructure: power (X-rays, utility, UPS, generators, PDUs), precision cooling (CRAC/CRAH, chillers), environmental sensors, fire detection and suppression, and building/security systems (BMS, access control, CCTV).

The position exists to analyse and own facility alerts escalated by L1 operators, drive incident resolution with ZATCA facilities teams and vendors, perform root cause analysis, and continuously improve monitoring coverage, thresholds and runbooks in the DCIM/BMS and monitoring tools,

so that facility-related risks to IT service availability are detected early, handled within SLA, and reported with complete evidence under the Managed Monitoring Service contract.


Key Duties & Responsibilities:


• Act as escalation point for facility alerts (power, cooling, temperature/humidity, leak, x-rays, fire, access/CCTV): analyses, confirm impact, set/adjust priority and lead incident handling to resolution.

• Coordinate with ZATCA facilities team, data centre operator and OEM/maintenance vendors during incidents; track actions and confirm recovery and return to normal state.

• Perform root cause analysis and issue problem/cause reports for P1/P2 facility incidents within 2 working days; follow up corrective and preventive actions.

• Configure and tune monitoring in DCIM/BMS and monitoring tools: device onboarding, thresholds, alarm rationalisation, dashboards and coverage gap closure.

• Produce facility health and capacity reports (power load, UPS/battery health, cooling capacity, rack thermal trends, PUE) and input to weekly/monthly KPI & SLA reports.

• Write and maintain smart-facilities SOPs, runbooks and escalation matrix entries; train and coach L1 operators and review the quality of their triage and records.

• Monitor planned maintenance and change windows (generator tests, UPS/battery maintenance, cooling works); assess monitoring impact and suppress/restore alerts in a controlled way.

• Take part in governance meetings, audits, DR/emergency drills and continuous-improvement initiatives; ensure compliance with ZATCA and NCA policies.


Job Requirements:


• Bachelor's in Electrical or Mechanical Engineering.

• CDCS / CDFOM, Uptime Institute (ATS/AOS), ITIL 4 Foundation, NFPA-related training.

• 10+ years, including monitoring of Tier III data centres.

• Government or financial-sector data centres; 24x7 managed services under SLA.

• Tier standards (Uptime / TIA-942), PUE and capacity planning, access control and CCTV systems.

• Schneider EcoStruxure, Siemens Desigo, Honeywell, Vertiv/Nlyte DCIM; Power BI dashboards.

• Fluent Arabic and English, including technical RCA reports.

• Experience presenting to client management and governance boards.

Join our Telegram channel Get the latest jobs as soon as they are posted Join

Similar Jobs

Mubasher Capital
Smart Facilities Monitoring SME
About Mubasher Capital
Egypt, Cairo
Financial Services